Most users rarely brand use of the time on their Windows machines because it's near never correct. Even after setting the time, it could tend to reset whenever y'all reboot your estimator.

Worse is when you try to update the fourth dimension manually, and it fails with errors. The issue throws the mistake 0x80070005 and states that you don't have access to perform the action. You lot tin likewise run across this trouble when you attempt to query the configuration of the Time Service (w32tm) in Command Prompt.

The Time service encountered and was forced to close down. The error was 0x80070005: Access is denied.

If you're presently facing issues synchronizing the Windows Time service, this guide shows you how to set up it.

Admission is denied when syncing time service w32Time, Mistake 0x80070005

The Time service encountered and was forced to shut down, Error 0x80070005

Let usa encounter how to set up Set Upshot ID 46, The Time service encountered and was forced to shut down, The error was 0x80070005, Access is denied when trying to sync Time effect on Windows x. Follow the steps below:

  • Re-annals the Windows Time service.
  • Re-annals the Windows Time service and its DLL file.
  • Query the Time service.
  • Synchronize external fourth dimension server.
  • Update the Windows Registry.

Don't worry if the above steps seem confusing. Read on to get a total breakup of the process.

Enter the post-obit commands in the Command Prompt window and hit ENTER after each line. I'll write out the commands and explain what they do.

1] Stop the Windows Time service:

stop w32time

two] Unregister the Windows Fourth dimension service:

w32tm /unregister

3] Exit Control Prompt.

four] Restart your calculator after unregistering the Time service.

5] Following the restart, open up Command Prompt as an Administrator, enter the post-obit 3 commands, and striking Enter:

6] Register the Fourth dimension service DLL file:

regsvr32 /u w32time.dll

7] Register the Fourth dimension service:

w32tm /annals

8] Query the status of the Time service:

sc query w32time

At this point, Control Panel volition display the Windows Time service as a shared process, and the Time service volition begin to showtime automatically on booting your machine. This means that the 0x80070005 (Access is denied) mistake volition disappear.

9] Y'all now have to restart your computer once more.

10] On restart, open the Control Prompt with elevated privileges and continue with the commands that follow:

Sync time for external sources:

pushd %SystemRoot%\system32 .\w32tm /config /update /manualpeerlist:"ntp0.cornell.edu,0x09 sundial.columbia.edu,0x09 ane.us.pool.ntp.org,0x09 2.the states.puddle.ntp.org,0x09? /syncfromflags:Transmission /reliable:aye .\w32tm /resync popd

11] Head over to the Windows Registry Editor and run information technology equally an Administrator.

Look for the following Registry primal:

HKEY_LOCAL_MACHINE\System\CurrentControlSet\Services\W32Time\TimeProviders\NtpClient\SpecialPollInterval

Supercede3600 to 900 to set the server polls for every 15-minute interval equally opposed to an hour.

This is of import if 0x80070005 your PDC runs on a virtual machine.

Read: Windows Time Service non working.

I hope this postal service helps yous resolve the effect.

The Time service encountered and was forced to shut down, Error 0x80070005

Keshi Ile is a seasoned technology expert who holds a Bachelors's degree in Electronics Engineering science and a Master's in Digital Marketing. He runs several net companies and contributes to technology blogs.